TCN-2HK expandable intelligent COD ammonia nitrogen analyzer

The TCN-2HK extensible intelligent COD ammonia nitrogen analyzer features a straightforward design, is dependable and consistent, and can precisely capture and interpret data. Uninterrupted spectrum in the wavelength range of 320-1100nm, COD ammonia nitrogen tester capable of qualitative and quantitative analysis of sample substances in the visible and near-infrared spectral regions; the device can expand more than 40 measurement procedures, including CODcr, ammonia nitrogen, total phosphorus, total nitrogen, residual chlorine, heavy metals, and numerous other testing items.

Principle of COD test: rapid resolution spectrophotometry
Water sample, potassium dichromate solution, silver sulfate solution (silver sulfate as a catalyst can be added more effectively to oxidize straight chain fat
Compound) and concentrated sulfuric acid mixture heated to 165℃, dichroic acid ion oxidation of organic compounds in the solution after the color will change, in the instrument measurement range, the degree of color change and COD concentration in the sample is proportional to, therefore, by spectrophotometry measurement of the degree of color change, you can calculate the concentration of COD in the sample.

Ammonia nitrogen test principle: Nesser's reagent spectrophotometry
Ammonia nitrogen in the form of free ammonia or ammonium ion reacts with Nessler's reagent to produce a reddish brown complex. The absorbance of the complex is proportional to the content of ammonia nitrogen, and the absorbance is measured at the wavelength 420nm.

Product Features

1.The photometer software system and the water quality rapid measurement software system coexist, and users can choose based on experience.
2.Water sample, potassium dichromate solution, silver sulfate solution (silver sulfate as a catalyst can be added more effectively to oxidize straight chain fat
Compound) and concentrated sulfuric acid mixture heated to 165℃, dichroic acid ion oxidation of organic compounds in the solution after the color will change, in the instrument measurement range, the degree of color change and COD concentration in the sample is proportional to, therefore, by spectrophotometry measurement of the degree of color change, you can calculate the concentration of COD in the sample.
3.Adopt 1024*768 pixel 8-inch color touch screen with full Chinese operation menu.
4.The app contains a built-in standard curve for water quality testing.
5.Colorimetric method: Colorimetric tubes (which integrate digestion and colorimetric processes in one tube) can be easily and quickly converted between large and small tubes without changing adapters.
6.Wavelength calibration: Automatically perform calibration.
7.Batch size: 6/16/25 samples optional.
8.Using intelligent PID temperature control technology and dual anti-overtemperature protection system, heating is safe, uniform and fast.
9.The light source adopts imported long-life tungsten lamp.
10.It has data storage function and can store 2000 sets of data.
11.Built-in micro printer for printing experimental results.
12.Data communication interface includes USB and RS-232.

Product Parameters

Model No. TCN-2HK
Wavelength range 320-1100nm
Wavelength Accuracy ±1nm
Wavelength repeatability ≤0.2nm
Photometric accuracy ±0.5%T
Photometric repeatability ≤0.2%T
Drift ≤0.001A/h
Spectral Bandwidth 4nm
Photometric display range 0-200%T, -0.3-3A, 0-9999C
Noise ±0.001Abs(500nm)
Stray light ≤0.1%T
Operating environment 10~40C, maximum 80% humidity, no condensation
Power requirements 100-240V/50-60HZ
Size 430mm×320mm×180mm
Weight 10kg

Measurement items and scope

NO. Measurement Item Measurement Scope Measurement Deviation Measurement lower limit
1 COD (Low measurement  range) 0-150mg/L ≤±5%     5
COD (Middle measurement range) 150-1500mg/L ≤±5%
COD(High measurement  range) 1500-15000mg/L ≤±5%
2 ammonia nitrogen(Low measurement  range) 0-5mg/L ≤±3% 0.05
ammonia nitrogen(Low measurement  range) 5-50mg/L ≤±3%

Application Scenario

factory (1)xu5

laboratory detection

factory (2)oj8

 sewage treatment works

factory (3)vi4

Wastewater monitoring;

factory (4)fq9

Scientific research and education

INTRODUCTION

Tianjin ShareShine Technology Development Co., Ltd. is a high-tech enterprise with independent innovation as the driving force and scientific and technological development as the core, which closely integrates "production, learning, research and application". The company has international first-class level in the field of spectrum detection technology and environmental monitoring technology. The company's main business covers environmental online monitoring instruments, environmental Internet of Things system solutions and intelligent operation and maintenance services.
The company has always adhered to independent innovation, focusing on the research and development and manufacturing of high-end environmental monitoring equipment. Widely used and service in power plants, sewage treatment plants, pharmaceutical, printing, textile, petrochemical, gas safety, underground pipe network, safety protection, precision manufacturing, mining and metallurgy, university research, ambient air and water treatment, light industry and electronics industry, water supply and drinking water distribution network, food and beverage, hospitals, hotels, aquaculture, new agricultural cultivation and biological fermentation Crafts and other industries.
hrty (1)y1w

Head Office

company (12)ic5

Optical Lab

companyitg

R&D 

work-shxxs

Production Workshop

company (11)clo

Chemistry Lab

por (1)0vx